Descripción
Product Features
| Product Type |
Materia Prima |
Product Categories |
PC |
CAS NO. |
67-07-2 |
| Manufacturers |
Covestro |
Grade |
ET3113 |
Place of Origin |
Germany |
| Appearance |
Transparent White |
Packing Size |
25/KG Standard Packaging |
Test Item Test Method Test Condition Test Unit Test Result
Rheological properties
|
Melt volume-flow rate
|
ISO 1133
|
300℃, 1.2kg
|
cm³/10minc
|
6.0
|
|
Melt index (mass)
|
ISO 1133
|
300℃, 1.2kg
|
g/10min
|
6.5
|
|
Molding shrinkage, parallel
|
ISO 294-4
|
60x60x2 mm/ 500 bar
|
%
|
0.7
|
|
Mold shrinkage, vertical flow direction
|
ISO 294-4
|
60x60x2 mm/ 500 bar
|
%
|
0.75
|
|
Molding shrinkage, parallel/normal
|
b.o. ISO 2577
|
–
|
%
|
0.6~0.8
|
Mechanical Properties
|
Tensile modulus
|
ISO 527-1,-2
|
1mm/min
|
MPa
|
2350
|
|
Yield stress
|
ISO 527-1,-2
|
50mm/min
|
MPa
|
65
|
|
Yield strain
|
ISO 527-1,-2
|
50mm/min
|
%
|
6.3
|
|
Nominal strain at break
|
ISO 527-1,-2
|
50mm/min
|
%
|
>50
|
|
Stress at break
|
ISO 527-1,-2
|
50mm/min
|
MPa
|
70
|
|
Strain at break
|
b.o. ISO 527-1,-2
|
50mm/min
|
%
|
130
|
|
Tensile creep modulus
|
ISO 899-1
|
1h
|
MPa
|
2200
|
|
Tensile creep modulus
|
ISO 899-1
|
1000h
|
MPa
|
1900
|
|
Flexural modulus
|
ISO 178
|
2mm/min
|
MPa
|
2350
|
|
Bending strength
|
ISO 178
|
2mm/min
|
MPa
|
96
|
|
Flexural strain at flexural strength
|
ISO 178
|
2mm/min
|
%
|
7.2
|
|
Flexural stress at 3.5 % strain
|
ISO 178
|
2mm/min
|
MPa
|
72
|
|
Charpy impact strength
|
ISO 179/1eU
|
23℃
|
KJ/m²
|
N
|
|
Charpy impact strength
|
ISO 179/1eU
|
-60℃
|
KJ/m²
|
N
|
|
Charpy notched impact strength
|
ISO 21305/based on ISO 179/1eA
|
23℃/3mm
|
KJ/m²
|
80P
|
|
Charpy notched impact strength
|
ISO 21305/based on ISO 179/1eA
|
-30℃/3mm
|
KJ/m²
|
18C(P)
|
|
Izod notched impact strength
|
ISO 21305/based on ISO 179/1eA
|
23℃/3mm
|
KJ/m²
|
70P
|
|
Izod notched impact strength
|
ISO 21305/based on ISO 179/1eA
|
-30℃/3mm
|
KJ/m²
|
20C(P)
|
|
Puncture impact properties – maximum force
|
ISO 6603-2
|
23℃
|
N
|
5600
|
|
Puncture impact properties – maximum force
|
ISO 6603-2
|
-30℃
|
N
|
6500
|
|
Puncture energy
|
ISO 6603-2
|
23℃
|
J
|
60
|
|
Puncture energy
|
ISO 6603-2
|
-30℃
|
J
|
70
|
|
Ball indentation hardness
|
ISO 2039-1
|
–
|
N/mm²
|
113
|
Thermal properties
|
Glass transition temperature
|
ISO 11357-1,-2
|
10 ℃C/min
|
℃
|
148
|
|
Heat distortion temperature
|
ISO 75-1,-2
|
1.8MPa
|
℃
|
128
|
|
Heat distortion temperature
|
ISO 75-1,-2
|
0.45MPa
|
℃
|
141
|
|
Vicat softening temperature
|
ISO 306
|
50 N; 50 ℃C/h
|
℃
|
148
|
|
Vicat softening temperature
|
ISO 306
|
50 N; 120 ℃C/h
|
℃
|
149
|
|
Vicat softening temperature
|
ISO 11359-1,-2
|
23 to 55 ℃C
|
10^-4/K
|
0.65
|
|
Linear Thermal Expansion Coefficient
|
ISO 11359-1,-2
|
23 to 55 ℃C
|
10^-4/K
|
0.65
|
|
Vicat softening temperature
|
UL 94
|
1.5 mm
|
Class
|
HB
|
|
Flammability test UL94 [UL recognized]
|
UL 94
|
0.75 mm
|
Class
|
V2
|
|
Vicat softening temperature
|
ISO 4589-2
|
Method A
|
%
|
28
|
|
Thermal conductivity, through plane
|
ISO 8302
|
23 ℃C; 50 % r. h.
|
W/(m·K)
|
0.20
|
|
Vicat softening temperature
|
IEC 60695-10-2
|
–
|
℃
|
140
|
|
Relative Temperature Index (Dielectric Strength)
|
UL 746B
|
1.5 mm
|
℃
|
125
|
|
Vicat softening temperature
|
UL 746B
|
1.5 mm
|
℃
|
115
|
|
Relative Temperature Index (Dielectric Strength)
|
UL 746B
|
1.5 mm
|
℃
|
125
|
|
Glow Wire Burn Index
|
IEC 60695-2-12
|
0.75 mm
|
℃
|
875
|
|
Glow Wire Burn Index
|
IEC 60695-2-12
|
1.5 mm
|
℃
|
875
|
|
Glow Wire Burn Index
|
IEC 60695-2-12
|
3.0 mm
|
℃
|
960
|
|
Glow Wire Burn Index
|
IEC 60695-2-13
|
0.75 mm
|
℃
|
875
|
|
Glow Wire Burn Index
|
IEC 60695-2-13
|
1.5 mm
|
℃
|
875
|
|
Glow Wire Burn Index
|
IEC 60695-2-13
|
3.0 mm
|
℃
|
900
|
|
Vicat softening temperature
|
DIN 53438-1,-3
|
Method K and F/ 2.0 mm
|
Class
|
K1, F1
|
|
Needle flame test
|
IEC 60695-11-5
|
Method K/ 2.0 mm
|
s
|
5
|
|
Needle flame test
|
IEC 60695-11-5
|
Method K/ 3.0 mm
|
s
|
10
|
|
Needle flame test
|
IEC 60695-11-5
|
Method F/ 1.5 mm
|
s
|
60
|
|
Needle flame test
|
IEC 60695-11-5
|
Method F/ 2.0 mm
|
s
|
120
|
|
Needle flame test
|
IEC 60695-11-5
|
Method F/ 3.0 mm
|
s
|
120
|
|
Vicat softening temperature
|
ISO 3795
|
>=1.0 mm
|
mm/min
|
passed
|
|
Flash ignition temperature
|
ASTM D1929
|
–
|
℃
|
480
|
|
Vicat softening temperature
|
ASTM D1929
|
–
|
℃
|
550
|
Relacionado